Products

SP1250DLE-MC

Our newest digital UPS is designed for ITS and traffic applications, including the new low-voltage ATC cabinets.

Clean Power for Low Voltage Cabinets

This model is also plug and play with McCain cabinets.  It’s the only double conversion, true on-line UPS with both AC and DC power inputs and outputs, and it comes in a compact 1U rack-mounted package.  The SP 1250DLE-MC is designed for temperature extremes of ‑40°C to +74°C (-40°F to +165°F) and supports 85-155 VAC or 48 VDC input voltages, as well as generator input. The unit provides two 120 VAC outputs, two 48 VDC outputs and one  24 VDC output, up to an 875 watt maximum for all outputs combined.

PRODUCT SPECIFICATIONS
  • Input #1

    Voltage
    85 - 155 VAC

    Frequency
    60 Hz ±5 Hz

    Power Factor
    Power factor corrected

    Input #2

    Voltage
    48 VCD nominal battery pack

    Isolation
    Thru-neutral design

  • Outputs – General

    Total Power
    875 W maximum all outputs combined

    Overload
    120% for 10 mins

    Isolation
    AC, 48 VDC and 24/12 VDC isolated from each other

    UPS Protection
    Input and output short circuit / Input and output overload

    AC Load #1 and #2

    Voltage
    120 VAC ±3%

    Frequency
    60 HzVA / Power1250 VA / 875 WTHD5% maximum

    Isolation
    Thru-neutral design

    UPS Protection
    Input and output short circuit / Input and output overload

    DC Output #1

    Voltage
    48 VDC ±3%

    Current
    8 A

    Power
    400 W

    DC Output #2

    Voltage
    48 VDC ±3%

    Current
    8 A

    Power
    400 W

    DC Output #3

    Voltage
    24 VDC ±3%

    Current
    6 A

    Power
    144 W

  • Temperature
    -40°C to +74°C (-40°F to +165°F)

    Humidity
    95% maximum, non-condensing

    Altitude
    -1000 to 10,000 ft

  • Cooling
    Forced air, Removable filter, Reversible direction

  • Standard Features
    Power factor corrected input, True on-line continuous power, Fully isolated DC output stages, Wide AC input operating range without battery use, High inrush current capability

    Typical Recharge Time
    (to 85% Capacity @ 100% Load)

    3 to 5 hrs with SP 485B battery pack, 48 to 72 hrs with Outpost or Garrison batteries

  • Visual Indicators
    Battery status, AC input, DC input, Load status, Fault indicators

    Switches / Control Panel
    System power, Cold start, Fault silence, Battery test, AC output, DC output

    Audible Alarms
    For fault conditions

    Intelligent Computer Interfaces
    ["Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software)"]

  • SNMP Interface
    ["Allows full control and monitoring interface over network connection. Compatible with HP Openview\u2122, IBM Netview\u2122, CA Unicenter TNG\u2122, and other major software offerings."]

PRODUCT DOWNLOADS
Manual (PDF)
Datasheet (PDF)
Next
Next

SP1250LE