ProductsSP1250DLE-MC
Our newest digital UPS is designed for ITS and traffic applications, including the new low-voltage ATC cabinets.
Clean Power for Low Voltage Cabinets
This model is also plug and play with McCain cabinets. It’s the only double conversion, true on-line UPS with both AC and DC power inputs and outputs, and it comes in a compact 1U rack-mounted package. The SP 1250DLE-MC is designed for temperature extremes of ‑40°C to +74°C (-40°F to +165°F) and supports 85-155 VAC or 48 VDC input voltages, as well as generator input. The unit provides two 120 VAC outputs, two 48 VDC outputs and one 24 VDC output, up to an 875 watt maximum for all outputs combined.
PRODUCT SPECIFICATIONS
-
Input #1
Voltage
85 - 155 VACFrequency
60 Hz ±5 HzPower Factor
Power factor correctedInput #2
Voltage
48 VCD nominal battery packIsolation
Thru-neutral design -
Outputs – General
Total Power
875 W maximum all outputs combinedOverload
120% for 10 minsIsolation
AC, 48 VDC and 24/12 VDC isolated from each otherUPS Protection
Input and output short circuit / Input and output overloadAC Load #1 and #2
Voltage
120 VAC ±3%Frequency
60 HzVA / Power1250 VA / 875 WTHD5% maximumIsolation
Thru-neutral designUPS Protection
Input and output short circuit / Input and output overloadDC Output #1
Voltage
48 VDC ±3%Current
8 APower
400 WDC Output #2
Voltage
48 VDC ±3%Current
8 APower
400 WDC Output #3
Voltage
24 VDC ±3%Current
6 APower
144 W -
Temperature
-40°C to +74°C (-40°F to +165°F)Humidity
95% maximum, non-condensingAltitude
-1000 to 10,000 ft -
Cooling
Forced air, Removable filter, Reversible direction
-
Standard Features
Power factor corrected input, True on-line continuous power, Fully isolated DC output stages, Wide AC input operating range without battery use, High inrush current capabilityTypical Recharge Time
(to 85% Capacity @ 100% Load)
3 to 5 hrs with SP 485B battery pack, 48 to 72 hrs with Outpost or Garrison batteries -
Visual Indicators
Battery status, AC input, DC input, Load status, Fault indicatorsSwitches / Control Panel
System power, Cold start, Fault silence, Battery test, AC output, DC outputAudible Alarms
For fault conditionsIntelligent Computer Interfaces
["Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software)"] -
SNMP Interface
["Allows full control and monitoring interface over network connection. Compatible with HP Openview\u2122, IBM Netview\u2122, CA Unicenter TNG\u2122, and other major software offerings."]