ProductsDT Series ET
The DT Series ET is a digital Uninterruptible Power System (UPS) which features Clary’s on-line double conversion, power factor corrected technology built for extreme temperature.
Built for Extreme Temperatures Where Others Have Failed
Not only does the DT Series ET offer the highest reliability available on the market today, we consider it on-line double conversion technology at its best. We’ve built this system for that application where all others have failed due to extreme indoor or outdoor environmental conditions.
PRODUCT SPECIFICATIONS
-
Voltage
120 VAC +12%, -25% (without battery discharge)Frequency
45 Hz to 65 HzCurrent
7.2 A -
Voltage
120 VAC ±3%Frequency
Software selectable to sync with input utility or run at crystal controlled 50/60 Hz ±1 HzCurrent
8.3 ACrest Factor Ratio
50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1THD
<1%Dynamic Response
±4% for 100% step load change 0.5 ms recovery timeOverload
110% for 10 sec; 200% for 50 msUPS Protection
Input and output short circuit, Input and output overload, Excessive battery discharge -
Temperature
-40°C to +74°C (-40°F to +165°F)Humidity
0% to 95% non-condensingAltitude
Sea level to 10,000 ftNoise Level
46 dBA at 5 ft -
Input
NEMA 5-15P plug with 6 ft cordOutputs
5-15R receptacles
-
Standard Features
Power factor corrected input, Fully regenerative, True on-line continuous power, Low distortion sine wave output, Designed for non-linear loads, Extended brownout protection, RS232 data interface, Inverter powers load continuously, Continuous operation on -25% to +12% utility without draining batteries, Automatic bypass, AC output (2 channel load control), Rear mounted ground studCertifications
FCC Class A, IEEE 587/ANSI C62.4, IEC 555 @ 120 VA, CUL, UL 1778MTBF
Inverter: > 100,000 hrsTypical Recharge Time
(to 85% Capacity @ 100% Load)
8 hrs (more time required with extended battery option) -
Visual Indicators
Battery level, Load level, AC in, Inverter on, Summary alarm, Alarm silence, Load onSwitches / Control Panel
System power, Cold start, Load I, Load II, Test, Alarm silenceAudible Alarms
Utility interrupt, Inverter failure, Overload, Low battery, Self testIntelligent Computer Interfaces
Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software)Contact Closures
Open collector (see user manual for additional interface information) -
SNMP Interface
Allows full control and monitoring interface over network connection. Compatible with HP Openview™, IBM Netview™, CA Unicenter TNG™, and other major software offerings.