Products

CMN Series

The Clary CMN Series Uninterruptible Power Systems are designed specifically for fixed and mobile military applications. Clary’s industrial-grade CMN Series is built and assembled to perform at the highest level in extreme temperatures and rugged environments.

Built for Military Applications in the Most Extreme Environments

All systems are reliable, digitally microprocessor-controlled online products designed to deliver clean, regulated power under all conditions. All CMN Series systems are Power Factor Corrected (PFC) in real-time to maximize efficiency. Full RS232 and SNMP interactive communication capabilities ensure support for a wide range of command-and-control applications.

PRODUCT SPECIFICATIONS
  • Voltage
    120 VAC +12%, -25% (without battery discharge)

    Frequency
    45 Hz to 65 Hz

  • Voltage
    120 VAC ±3%

    Frequency
    Software selectable to sync with input utility or run at crystal controlled 50/60 Hz ±1 Hz

    Crest Factor Ratio
    50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1

    THD
    3.00% maximum (linear), 5.00% maximum (non-linear)

    Dynamic Response
    ±4% for 100% step load change 0.5 ms recovery time

    Overload
    110% for 10 sec; 200% for 50 ms

    UPS Protection
    Input and output short circuit, Input and output overload, Excessive battery discharge

  • Temperature
    -40°C to +74°C (-40°F to +165°F), 0°C to +50°C (+32°F to +122°F)

    Humidity
    0% to 95% non-condensing

    Altitude
    Sea level to 10,000 ft

    Noise Level
    46 dBA at 5 ft

  • Input
    Consult factory

    Outputs
    Consult factory

  • Standard Features
    Power factor corrected input, Fully regenerative, True on-line continuous power, Low distortion sine wave output, Designed for non-linear loads, Extended brownout protection, RS232 data interface, Inverter powers load continuously, Continuous operation on -25% to +12% utility without draining batteries, Automatic bypass, AC output (8 channel load control), Rear mounted ground stud

    Certifications
    FCC Class A, IEEE 587/ANSI C62.4, IEC 555@ 120 VA, CUL, UL 1778

    Typical Recharge Time
    (to 85% Capacity @ 100% Load)

    8 hrs (more time required with extended battery option)

  • Visual Indicators
    Battery level, Load level, AC in, Inverter on, Summary alarm, Alarm silence, Load on

    Switches / Control Panel
    System power, Cold start, Load I, Load II, Test, Alarm silence

    Audible Alarms
    Utility interrupt, Inverter failure, Overload, Low battery, Self test

    Intelligent Computer Interfaces
    RS232 data interface (DB-9), Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software), Compatible with Systems Enhancement™ UPS control software

    Contact Closures
    DB-9, Open collector

  • SNMP Interface
    Allows full control and monitoring interface over network connection. Compatible with HP Openview™, IBM Netview™, CA Unicenter TNG™, and other major software offerings.