The SP Series Model PD UPS and Outpost™ Series batteries are designed for outdoor use and will operate in extreme temperature environments of
-40°C to +74°C. (-40°F to + 165°F)

SP1000PD-R/N - SP1250PD-R/N PLUS - SP2000PD-R/N
UPS Systems for LED Traffic Signal
• Can keep an intersection running for up to 8 hours or longer
• Does not compromise existing cabinet wiring
• Provides ON-LINE conditioned re-manufactured power for cabinet equipment
• RS232 or TCP/IP- Communicates with monitoring center or other equipment
• SP1000PD-R/N: 1,250 VA, 875 Watts, continuous power
• SP1250PD-R/N PLUS: 1,250 VA, 875Watts (1400 watts, peak load 10 sec. or less)
• SP2000PD-R/N: 2,000 VA, 1,400 Watts, continuous power
• Multi-state DOT and NEMA compliant
• Optional NEMA 3R Type II and Type III cabinets available
• Power Factored Corrected

Outpost™ Series
AGM VRLA Batteries for Traffic Applications -40°C to +74°C (-40°F to +165°F)
• Designed for outdoor applications
• Outlives any other battery in extreme environments
• Special connectors allow safe, rapid field replacement
• Configured in a set of six batteries (SP1000PD-R/N & SP1250PD-R/N PLUS)
• Configured in a set of eight batteries (SP2000SR/SN/U)

SP1000PD-R/N - SP1250PD-R/N PLUS
Keeping intersections alive during power failures, Clary's SP Series Model PD is the world’s most advanced Uninterruptible Power System (UPS) for traffic applications. Without compromising existing cabinet wiring, the SP Series, Model PD, keeps LED signal heads running for up to 8 hours or more during power failures. Clary's continuous power systems fit inside most existing cabinets and meet all NEMA temperature specifications. Optional NEMA 3R Type II and Type III cabinets are available.

These systems also provide clean, regulated power for controllers and other sensitive equipment inside the cabinet. The SP1000PD-R/N systems are intended for application where load usage will not exceed 875 watts. These systems are also available with an extended load option the SP1250 PD-R/N PLUS will allow for 1400 watts peak load for a ten second interval. This option accommodates intersections that have not yet replaced the yellow incandescent traffic lamps. Additionally, Clary can provide a SP2000PD-R/N system that will sustain a continuous 1400 watt load. These systems require eight batteries and additional cabinet space or a separate cabinet such as the CBO-123 UPS cabinet.

Advanced communication features allow monitoring, configuration and control of the system over RS232, modem or network connections SNMP Product Brochure.

The SP Series, Model PD integrates the PIM function into the standard chassis.
The Power Interface Module (PIM) is designed and manufactured to interface cabinet utility power to the SP Series traffic systems and to control the output utility power within the traffic cabinet.

OUTPOST BATTERIES
These 41Ah maintenance-free, Absorbent Glass Mat, Valve Regulated, Lead Acid (AGM-VRLA) batteries are designed for deep cycle, extreme temperature applications. They have been field tested and used for years by the military. Absorbed Glass Mat (AGM) technology assures a safe environment. Especially designed for outdoor and extreme temperature applications, they are capable of operating from -40°C to +74°C (-40°F to +165°F). This makes them ideal for use with Clary’s SP Series Model PD Traffic Signal solutions, IT/Communication UPS solution or other extreme temperature applications.



WARRANTY | PRODUCT MANUALS | PRODUCT BROCHURE

   
 
  ELECTRICAL    
  INPUT    
  Voltage Ranges     120 VAC +12%, -25% (without battery discharge)
  Frequency     48 to 62 Hz
  OUTPUT    
  Voltage     120 VAC ±3%
  Frequency     50 or 60 Hz
  Rating    

1,250 VA/875 Watts
1,250 VA/875 Watts or 1400 Watts for 10 seconds
2,000 VA/1400 Watts

  Crest Factor Ratio (Non-linear Load and < 5% THD) Typical    
@50% Load Up to 4.8:1
@75% Load Up to 3.2:1
@100% Load Up to 2.4:1
  Total Harmonic Distortion (THD)     4.0% Max.
  Dynamic Response     ±4% for 100% Step Load Change 0.5 ms Recovery Time
  Overload     110% for 10 min; 200% for .05 sec
  UPS Protection     Input and Output Short Circuit; Input and Output Overload; Excessive Battery Discharge
  ENVIRONMENTAL    
 

Operating Temperature

   

-40°C to +74°C (-40°F to+165°F)

  Humidity     0% to 95% Non-condensing
  Altitude     Sea Level to 10,000 ft (some derating of temp. w/altitude > 6,000 ft)
  MECHANICAL    
  Input Connectors     Hardwired to PIM
  Outputs(Standard)     Hardwired to PIM, w/single 15 Amp Receptacle
  Cabinet     NEMA, 332 or CBO-126 Cabinet Style Configurations Available; NEMA 3R Type II and Type III Optional
  CUSTOM OPTIONS    
  Consult Factory for other Custom options      
  DESIGN    
  Standard Features     Power Factor Corrected Input; Fully Regenerative; True On-Line Continuous Power; Low Distortion Sinewave Output; Designed for Non-linear Loads; Extended Brownout Protection; EIA/RS232 Data Interface
  Specifications     Meets FCC Class A, IEEE 587/ANSI C62.4, IEC 555@ 120 VAC and NEMA Stds
  MTBF     Inverter: > 100,000 hrs System w/Bypass: 150,000 hrs Calculated from Component Spec
  Typical Recharge Time
85% Capacity @100% Load
    48-72 hrs (more time required with extended battery option), Less than 20 hrs with optional Fast Battery Charger
  CONTROL AND INDICATORS    
  Ramping LEDs Single LEDs     Battery Level; Load Level AC In; Inverter On; Low Battery and Summary Alarm; Alarm Single LEDs Alarm Silence
  Control Panel     Power On; Cold Start; Test; Alarm Silence; Event Counter (w/Reset); Hour Meter; Battery Disconnect
  Audible Alarms     Utility Interrupt; Inverter Failure; Overload; Low Battery; Self Test
  Serial Interface for EIA 232. Optional via Standard RJ45     Full Interactive Remote Computer Monitoring and Control of Most Features Including EIA 232.Optional Load Control (requires optional monitoring software); NTCIP and TCP/IP Ready
  Contact Closures On Battery, ("D" connector)
    Open Collector for Remote Annunciation of Power Up, Power Down, On Battery, Low (“D” connector) Battery and Alarms
 

Specifications subject to change without prior notice.

   

 

Model
VA
Watts
Input
Current
(A)
Output
Current
(A)
Backup Time
100% / 50%
Load
Unit
Weight
(lbs)
Dimensions
H x W x D
(inches)
S1000PD
1,250
875
8.8
10.4
2.0 hrs./ 4.0 hrs.
27
6.00 x 19.0 x 10.0
SP1250PD (PLUS)
1,250
875/1400
8.8
10.4
2.0 hrs./ 4.0 hrs.
27
6.00 x 19.0 x 10.0
SP2000PD
2,000
1400
14.3
16.7
1.0 hrs./ 3.5 hrs.
28
6.00 x 19.0 x 10.0
 