The SP U-MPL UPS system with Power Channel Technologyis designed for indoor or outdoor use and will operate in harsh temperature environments of 0°C to +60°C (32°F to + 122°F).

SP1250U-MPL - SP1500U-MPL - SP2000U-MPL - SP2400U-MPL
The SP U-MPL Series is a unique "one of a kind" system providing on-line UPS back-up power with eight individually switched loads. Power Channel Technology provides users with the ability to transition eight individual loads locally, via front panel load switches or remotely, via TCP/IP over the internet from any where in the world. This technology provides for remote control of automated process when those process need to be reset or restarted. This process also allows for local or remote load shedding when the system is on batteries to further extend back-up time. The SP1250U-MPL systems are intended for application where load usage will not exceed 875 watts. The SP1500U-MPL will allow for 1050 watts peak load, while the SP2000U-MPL will allow for 1400 watts peak load and the SP2400U-MPL will allow for 1680 watts peak load.

Advanced communication features allow monitoring, configuration and control of the system over RS232, modem or network connections SNMP Product Brochure.

SP1250U-MPL - SP1500U-MPL - SP2000U-MPL - SP2400U-MPL
UPS Systems for Load control applications
• Can back-up systems for up to 8 hours or longer
• Eight individual loads controlled locally or remotely via TCP/IP
• Provides ON-LINE conditioned re-manufactured power
• RS232 or TCP/IP- Communicates with monitoring center or other equipment
• Power Factored Corrected

Outpost™ Series
AGM VRLA Batteries for Traffic Applications -40°C to +74°C (-40°F to +165°F)
• Designed for outdoor applications
• Outlives any other battery in extreme environments
• Special connectors allow safe, rapid field replacement
• Configured in a set of six batteries (SP1250U-MPL - SP1500U-MPL)
• Configured in a set of eight batteries (SP2000U-MPL - SP2400U-MPL)

OUTPOST® BATTERIES
These 41Ah maintenance-free, Absorbent Glass Mat, Valve Regulated, Lead Acid (AGM-VRLA) batteries are designed for deep cycle, extreme temperature applications. They have been field tested and used for years by the military. Absorbed Glass Mat (AGM) technology assures a safe environment. Especially designed for outdoor and extreme temperature applications, they are capable of operating from -40°C to +74°C (-40°F to +165°F). This makes them ideal for use with Clary’s SP Series Traffic Signal solutions, IT/Communication UPS solutions or other extreme temperature applications.



WARRANTY | PRODUCT MANUALS | PRODUCT BROCHURE

   
 
  ELECTRICAL    
  INPUT    
  Voltage Ranges     120 VAC +12%, -25% (without battery discharge)
  Frequency     48 to 62 Hz
  OUTPUT    
  Voltage     120 VAC ±3%
  Frequency     50 or 60 Hz
  Rating    

SP1250U-MPL - 1,250 VA/875 Watts, SP1500U-MPL - 1,500 VA/1050 Watts,
SP2000U-MPL - 2,000 VA/1400 Watts & SP2400U-MPL - 2400VA/1680 Watts

  Crest Factor Ratio (Non-linear Load and < 5% THD) Typical    
@50% Load Up to 4.8:1
@75% Load Up to 3.2:1
@100% Load Up to 2.4:1
  Total Harmonic Distortion (THD)     4.0% Max.
  Dynamic Response     ±4% for 100% Step Load Change 0.5 ms Recovery Time
  Overload     110% for 10 min; 200% for .05 sec
  Efficiency @100% Load     90% (Normal Mode)
  UPS Protection     Input and Output Short Circuit; Input and Output Overload; Excessive Battery Discharge
  ENVIRONMENTAL    
 

Operating Temperature

   

0°C to +60°C (32°F to+122°F)

  Humidity     0% to 95% Non-condensing
  Altitude     Sea Level to 10,000 ft (some derating of temp. w/altitude > 6,000 ft)
  Noise Level     46 dBA at 5 ft
  MECHANICAL    
  Input Connectors     L5-30P Inlet Connector
  Outputs(Standard)     Eight NEMA 5-15R Receptacles
  Cabinet     NEMA, 332 or CBO-123 Cabinet Style Configurations Available; NEMA 3R Type II and Type III Optional
  CUSTOM OPTIONS    
  Consult Factory for other Custom options      
  DESIGN    
  Standard Features     Power Factor Corrected Input; Fully Regenerative; True On-Line Continuous Power; Low Distortion Sinewave Output; Designed for Non-linear Loads; Extended Brownout Protection; EIA/RS232 Data Interface
  Specifications     Meets FCC Class A, IEEE 587/ANSI C62.4, IEC 555@ 120 VAC and NEMA Stds
  MTBF     Inverter: > 100,000 hrs System w/Bypass: 150,000 hrs Calculated from Component Spec
  Typical Recharge Time
85% Capacity @100% Load
    48-72 hrs (more time required with extended battery option), Less than 20 hrs with optional Fast Battery Charger
  CONTROL AND INDICATORS    
  Ramping LEDs Single LEDs     Battery Level; Load Level AC In; Inverter On; Low Battery and Summary Alarm; Alarm Silence
  Control Panel     Power On; Cold Start; Test; Alarm Silence; Event Counter (w/Reset); Hour Meter; Battery Disconnect
  Audible Alarms     Utility Interrupt; Inverter Failure; Overload; Low Battery; Self Test
  TCP/IP Interface standard via RJ45     Full Interactive Remote Computer Monitoring and Control of Most Features Including Load Control; NTCIP and TCP/IP Ready
  Contact Closures On Battery, ("D" connector)
    Open Collector for Remote Annunciation of Power Up, Power Down, Low Battery and Alarms
 

Specifications subject to change without prior notice.

   

 

 
 