The Clary S Series UPS is the only UPS of its class to offer medical grade performance. This reliable power system is built to the highest quality standards. S Series systems are typically found in patient care areas, medical laboratories, nurse stations, medical or dental offices and are intended for non life support applications.

Features:
• Keeps equipment running at all times
• Improves power quality
• Protects all connected equipment
• Easy installation in the office or lab environment
• No interrupted procedures
• Enhanced patient security
• No invalid test result
• No revenue disruption

pp

DIAGRAMS: Tower Style Tall Chassis   Block Diagram
WARRANTY | PRODUCT MANUALS | PRODUCT BROCHURE

   
 
FEATURES
BENEFITS
Input Voltage Range
120 VAC +12%, -25%; 90 to 135 VAC before switching to batteries
Assures continuous system operation during electrical surges and sags without switching to the batteries and depleting their capacity.
True On-Line Technology
True On-Line means Fully Regenerative, Dual Conversion operation. It assures complete isolation from voltage and frequency variations. Unlike “line-interactive,” “off-line” or “standby” systems, there is absolutely no interruption of power output or shift in line frequency to cause system crashes or resets. Complete compatibility with emergency standby generator systems is assured.
Full Microprocessor Control
Every aspect of system operation is monitored and controlled by the internal microprocessor. This assures flawless operation regardless of load, environmental or input power conditions. Clary has over 30 years experience designing with Digital Technology, which ensures reliability.
Power Factor Correction
Power Factor Correction eliminates distortion and harmonic currents caused by today’s high-tech loads. Eliminating this distortion assures that all of your equipment works together without problems. It also reduces your energy bill.
Communication and Control Interface’s
Allows interactive system control over a variety of network connections and communication interfaces - RS-232 (standard), Contact Closure and TCP/IP - SNMP (optional).
Complete Power Distribution Center
Six NEMA 5-15R connectors on two separate circuits are standard.
Remote Control of Receptacles (Two Circuits)
Each row of output connectors can be individually switched on or off at the front panel. Locked-up devices are a fact of life and this control allows the user to reboot devices powered by the UPS. Using a communications link, a remote operator (and/or network administrator) can also control and monitor each circuit.
Long Life Internal Batteries Options

Special VRLA batteries that offer longer discharge and float life allow full system operation during blackouts and severe brownouts. (See specification page for run time.)

Additional Battery Options
For applications that require longer operation during a power outage, additional matching battery packs that can be connected to the rear panel and extend run times are available.
SNMP Options

SNMP capability via TCP/IP Network connection. Compatible with more software than any other UPS including; HP Openview™, CA Unicenter TNG™ and other major software packages. SNMP Product Brochure

 