Larger VA rated products that also feature all-digital On-Line Double Conversion Technology. Designed to provide maximum performance and reliability with Power Factor Correction. Fully isolated output, and a wide range of input and output voltage and frequency selection options are also available. Ideally suited for server farms, telecommunication applications and many other mission-critical applications where reliability is a must! Available in Tower configuration. RATINGS: 6 kVA; input voltages of 208 and 240Vac are standard and output voltages of 120/208/220/230/240 VAC; 50/60 Hz. UL listed.

• True On-line Double Conversion
• Supports Redundant Parallel Architecture (RPA)
• Symmetrical or N+1 Capability
• Protects all connected equipment
• Superior Battery Management
• No interrupted procedures
• Enhanced patient security
• No invalid test result
• No revenue disruption
• Manual maintenance bypass switch

DIAGRAMS: Front and Rear Panel Operations Indicators
WARRANTY | PRODUCT MANUALS | PRODUCT BROCHURE

   
 
FEATURES
BENEFITS
Redundant Parallel Architecture (RPA), Optional (including bypass circuit)
Makes it possible to connect the output of up to four units in parallel. This provides maximum reliability because of redundancy of the system. Not only are the inverters redundant but so is the by-pass logic control and the battery systems. RPA protects your investment because parallelism supports future up grade ability allowing for investment only when you need it.
Superior Battery Management Features:
The S Series Superior Battery Management (SBM) provides enhanced battery lifetime which increases the economical life cycle of your investment
1.Monthly Automatic Battery and Calibration Testing
You will know before loss of data that the batteries need to be replaced. Batteries wear out! This feature provides an exact update of the actual battery capacity, which enables accurate runtime prediction.
2. Boost Charging
Boost charging enables fast recharging of the batteries. In this way the S603 Series can also backup the next blackout in a shorter period of time.
3.Temperature Compensated Battery Charger
This feature provide for the most optimal charging of the batteries which improves battery life.
4. Load Dependent End-of-Discharge Voltage
This feature provide for maximum battery capacity without over charging. Repeated over-charging will result in failure to recover normal battery capacity and reduces battery life.
5. No Load Shutdown
Improves battery life by preventing needless battery discharge in cases where there is no load or no utility power.
ECO Modes
By selecting the ECO-mode the S603Series operates on bypass continuously. On ECO-mode the unit has a very high efficiency providing low energy usage. The less heat generated also saves on air conditioning energy costs. An excellent feature when applied to less critical loads, like emergency lighting.
True On-line Double Conversion
Provides for the maximum system protection possible. Protects your equipment from damage due to any disturbance from the commercial power.
Protection against Overload, Short-circuit and Over-temperature
Over-load, short-circuit and over temperature protection reduces maintenance costs, and improves reliability.
RS232 / SNMP Compatible Communication Interfaces
Allows for monitoring and management of the UPS via the network, using the SNMP protocol set. RS232 is standard while the SNMP Interface is optional.
Emergency Power Off Feature (EPO)
Makes it possible to connect the S603 Series to a fire alarm system should safety reasons require UPS shutdown
 

150 East Huntington Drive. | Monrovia,CA 91016 | Tel:800-442-5279 or 626-359-4486 | Fax:626-305-0254

Terms of Use COPYRIGHT © 2004 CLARY Corporation All rights reserved