The S1500-601 is an on-line tower unit measuring 14” high by 7” wide by 21” deep and weighs 80 pounds.  It supports 1500VA or 1050 watts of load for 7 minutes of back-up time, and also supports either 120Vac or 230Vac input auto selecting, in fact, it will support input voltages as low as 96Vac and as high as 264Vac.  Output voltage is 120Vac.  This is a very low leakage unit that supports devices that directly contact the patient.  The S1500-601 also supports input from generator power, and because the S1500-601 is an on-line unit it protects the devices connect to it by eliminating electrical anomalies that harm or destroy that costly equipment.

Features:
• Keeps equipment running at all times
• Improves power quality
• Protects all connected equipment
• Easy installation in the office or lab environment
• No interrupted procedures
• Enhanced patient security
• No invalid test result
• No revenue disruption

 

DIAGRAMS: Tower Style Tall Chassis   Block Diagram
WARRANTY | PRODUCT MANUALS | PRODUCT BROCHURE

   
 
  ELECTRICAL    
  INPUT    
  Voltage Ranges     120 VAC +12%, -25% (without battery discharge)
  Frequency     45 to 65 Hz
  Current     See Table Below, Power Factor Corrected per IEC 555 @ 120 VAC
  OUTPUT    
  Voltage     120 VAC ±3%
  Frequency     Software Selectable to Sync with Input Utility or Run at Crystal Controlled 50/60 Hz ±1 Hz
  Current     See Table Below
  Crest Factor Ratio (Non-linear Load and < 5% THD) Typical    
@50% Load Up to 4.8:1
@75% Load Up to 3.2:1
@100% Load Up to 2.4:1
  Total Harmonic Distortion (THD)     3% Max. (Linear)
5% Max. (Non-linear)
  Dynamic Response     ±4% for 100% Step Load Change 0.5 ms Recovery Time
  Overload     110% for 10 min; 200% for .05 sec
  Efficiency @100% Load     88%
  UPS Protection     Input and Output Short Circuit; Input and Output Overload; Excessive Battery Discharge
  ENVIRONMENTAL    
 

Operating Temperatures:

   

± 0°C to +50°C (+32°F to +122°F)

  Humidity     0% to 95% Non-condensing
  Altitude     Sea Level to 10,000 ft (some derating of temp. w/altitude)
  Noise Level     39 to 42 dBA at 5 ft
  MECHANICAL    
  Input Connectors      
  2,000 . 2,400VA     NEMA 5-20P Plug w/6 ft Cord
  1,000/1,250/1,500 VA     NEMA 5-15P Plug w/6 ft Cord
  Outputs(Standard)     (1) Duplex hospital grade receptacle 5-15R, 1K-1.5K - 5-20R, 2K-2.4K
         
  CUSTOM OPTIONS    
  Hardwire Input/output; Input Circuit Breaker; Emergency Power Off Connection; Input Air Filter, Slide Rail Kit; Contact Factory for Other Custom Options      
  DESIGN    
  Standard Features     Power Factor Corrected Input; Fully Regenerative; True On-Line; Low Distortion Sinewave Output; Inverter Powers Load Continuously; Designed for Non-linear Extended Brownout Protection; Continuous Operation on -25% to +12% Utility w/o Draining Batteries; Automatic Bypass; RS232 Data Interface; AC Output - 2 Channel Load Control; Rear Mounted Ground Stud
  Specifications     UL-60601-1; UL-1778; FCC Class A; IEEE 587/ANSI C62.41; IEC 555@120 VAC
  MTBF     In Excess of 100,000 hrs
  Typical Recharge Time
85% Capacity @100% Load
    8 hrs (more time required with extended battery option)
  CONTROL AND INDICATORS    
  Sequenced LEDs Single LEDs     Battery Level; Load Level AC In; Inverter On; Load On; Summary Alarm; Alarm Silence
  Front Panel Controls     Power On; Cold Start; Alarm Silence; Test; Load I On-Off; Load II On-Off Controls
  Audible Alarms     Utility Interrupt; Inverter Failure; Overload; Low Battery; Self Test
  RS-232 Data Interface (DB-9)     Full Interactive Remote Computer Monitoring and Control of Most Features, Including Load Control (requires optional monitoring software). Compatible with: Systems Enhancement™ UPS Control Software.
  Contact Closure (DB-9)     Open Collector; Optional Dry Contact
  Optional SNMP Interface     Allows Full Control and Monitoring Interface over Network Connection. Compatible with HP Openview™, IBM Netview™, CA Unicenter TNG™, and other major software offerings.
 

Specifications subject to change without prior notice.

   

 

Model
VA
Watts
Input
Current
(A)
Output
Current
(A)
Backup Time
100% / 50%
Load
Unit
Weight
(lbs)
Dimensions
H x W x D
(inches)
S1500-601
1,500
1,050
10.7
12.5
5 / 17
80
14.1 x 6.9 x 21
 