120 VAC +12%, -25%; 90 to 135 VAC before switching to batteries
Assures continuous system operation during electrical
surges and sags without switching to the batteries and
depleting their capacity. |
|
|
|
 |
| True On-Line means Fully Regenerative, Dual Conversion
operation. It assures complete isolation from voltage
and frequency variations. Unlike “line-interactive,”
“off-line” or “standby” systems,
there is absolutely no interruption of power output or
shift in line frequency to cause system crashes or resets.
Complete compatibility with emergency standby generator
systems is assured. |
|
| Full Microprocessor Control |
|
 |
| Every aspect of system operation is monitored and
controlled by the internal microprocessor. This assures
flawless operation regardless of load, environmental or
input power conditions. Clary has over 30 years experience
designing with Digital Technology, which ensures reliability. |
|
|
|
 |
| Power Factor Correction eliminates distortion and harmonic
currents caused by today’s high-tech loads. Eliminating
this distortion assures that all of your equipment works
together without problems. It also reduces your energy
bill. |
|
| Communication and Control Interface’s |
|
 |
| Allows interactive system control over a variety of
network connections and communication interfaces - RS-232
(standard), Contact Closure and TCP/IP - SNMP (optional). |
|
| Complete Power Distribution Center |
|
 |
| Two NEMA 5-15R/6-20R connectors on two separate circuits
are standard. |
|
Remote Control of Receptacles (Two Circuits)
|
|
 |
| Each row of output connectors can be individually switched
on or off at the front panel. Locked-up devices are a
fact of life and this control allows the user to reboot
devices powered by the UPS. Using a communications link,
a remote operator (and/or network administrator) can also
control and monitor each circuit. |
|
| Long Life Internal Batteries Options |
|
 |
| Special VRLA batteries that offer longer discharge
and float life allow full system operation during blackouts
and severe brownouts. (See specification page for run
time.)
|
|
| Additional Battery Options |
|
 |
| For applications that require longer operation
during a power outage, additional matching battery packs
that can be connected to the rear panel and extend run
times are available. |
|
|
|
 |
SNMP capability via TCP/IP Network connection.
Compatible with more software than any other UPS including;
HP Openview™, CA Unicenter TNG™ and other
major software packages. SNMP Product Brochure
|
|