SP U-MPL

Transition up to 8 individual loads locally or remotely

SP U-MPL Overview

Clary’s SP U-MPL System is built with Power Channel Technology™ which provides users with the ability to transition eight individual loads locally, via front panel load switches or remotely, via an installed SNMP Adapter providing TCP/IP over the internet. This technology enables remote control of automated processes when those processes need to be reset or restarted. This process also allows for local or remote load shedding when the system is on batteries in order to further extend back-up time.

Available in 4 models from 1250VA/875 Watts to 2000VA/1680 Watts, the SP U-MPL has an operational temperature range of 0°C to +60°C(32°F to + 122°F), and will fit inside most existing cabinets, meeting all NEMA temperature specifications.

Advanced communication features allow monitoring, configuration and control of the system over RS232, modem or network connections. See our SNMP Product Brochure. Available for both NEMA and 332 style cabinets.


SP U-MPL Specifications

Voltage 120 VAC +12%, -25% (without battery discharge)
Frequency 48 Hz to 62 Hz
Voltage 120 VAC ±3%
Frequency 50 Hz or 60 Hz
Crest Factor Ratio 50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1
THD 5.00% maximum
Dynamic Response ±4% for 100% step load change 0.5 ms recovery time
Overload 110% for 10 sec; 200% for 50 ms
UPS Protection Input and output short circuit; input and output overload; excessive battery discharge
Temperature 0°C to +60°C (+32°F to +122°F)
Humidity 0% to 95% non-condensing
Altitude Sea level to 10,000 ft
Noise Level 46 dBA at 5 ft
Input NEMA 5-20P plug on 6 ft cord
Outputs 5-15R receptacles
Cabinet NEMA, 332 or CBO-123 cabinet style configurations available, NEMA, 3R Type II and Type III optional
Standard Features Power factor corrected input, Fully regenerative, True on-line continuous power, Low distortion sine wave output, Designed for non-linear loads, Extended brownout protection, EIA/RS232 data interface
Certifications FCC Class A, IEEE 587/ANSI C62.4, IEC 555@ 120 VA, NEMA
MTBF Inverter: > 100,000 hrs, System with bypass: 150,000 hrs
Typical Recharge Time to 85% Capacity @ 100% Load 48-72 hrs (more time required with extended battery option), < 20 hrs (with optional fast battery charger)
Ramping LEDs Single LEDs Battery level, Load level AC in, Inverter on, Low battery, Summary alarm, Alarm silence
Switches / Control Panel System power, Cold start, Test, Alarm silence, Event counter with reset, Hour meter, Battery disconnect
Audible Alarms Utility interrupt, Inverter failure, Overload, Low battery, Self test
Intelligent Computer Interfaces Serial interface for EIA 232, Optional NTCIP and TCP/IP via standard RJ45 connector, Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software), NTCIP and TCP/IP ready
Contact Closures "D" connector, Open collector (see user manual for additional interface information)
Model VA Watts Input Current Output Current Rating Backup Time* 100% / 50% Load Weight (lb) Rackmount H x W x D (in)
SP 2400U-MPL 2400 1680 20.0A 20.0A 2400 VA / 1680 W 1.2 hours / 4.0 hours 40 5.25 x 19.0 x 18.5
SP 2000U-MPL 2000 1400 14.3A 20.0A 2000 VA / 1400 W 1.4 hours / 4.1 hours 40 5.25 x 19.0 x 18.5
SP 1500U-MPL 1500 1050 8.8A 10.4A 1500 VA / 1050 W 1.5 hours / 3.5 hours 40 5.25 x 19.0 x 18.5
SP 1250U-MPL 1250 875 8.8A 10.4A 1250 VA / 875 W 1.5 hours / 3.5 hours 40 5.25 x 19.0 x 18.5

* Backup time is based on 41Ahr batteries


Contact us to learn more about our innovative products!